Heating Controls & Valves

Product Characteristics

1Use of radio frequency(RF) card, eliminates the defect that the ineterface (used for contact between the smart card and the valve) is easy to get tampered with.
2Utilizing the smart card to fulfil the prepayment function, with built-in clock circuit, the controller shuts the valve off automatically after it reaches the set ending date of heat distribution.
3Each valve is assigned with an unique smart card and an address to facilitate the consumption payment and management.
4Valve body uses of throughflow sensor design, delivers almost zero pressure drop
5Valve body uses of ultra thick design, ensures high intensity.
6Use of large torque of actuator ensuring that the valve can work properly under all kinds of working pressure.
7Factory-fitted M-BUS lead communication interfaces, facilitates the remote reading, billing and control.
8Allows the authority to remotely handle with emergent or coercive shut on/off the valve according to the practical condition.
9Equipped with interface for external DC24V power supply, drastically prolongs the life time of the built-in 3.6V lithium battery. Boosts the stability and reliability of the long-term running of the system.
10Built-in 3.6V standby lithium battery, facilitates the normal operations of the card reading and the valve activities in case powered off.
11Can work separately in either the remote control or control by smart card fashion. i.e. it can be used as the heating control valve in case of communication failure as well as it can remotely load credits and shut on/off the valve in case there is no smart card.
12Valve can be remotely controlled through the management system, enabling mass credit loading or activities control.
13Integrated compact structure design, excellent sealing to deliver highly resistant to water.
14LED light indications for valve on/off status are available, communication status, card reading status.
15Networking and power line uses of specialized 4-core waterproofing bus lead plug, facilitates the networking.
16Built-in temperature sensor to measure water temperature in the valve body, enabling the authority to capture the water distribution
17Built-in alarm circuit to alert of tampering attempts, it logs the current status timely when the controller is are separated from the valve body, and reports to the collector, the authority can handle with it timely after finding the issue through the management system.
18Built-in control circuit of the valve opening level and indication of the valve opening level, authority can set the maximum opening level of the customer's valve, achieves the purpose of saving energy. 

Technical Parameters

Nominal diameter
DN20, DN25
Standby current
15uA(LED light off)
Model classification
Electric ball valve
Protection class
IP54
Display type
LED indicating light
Battery life
6 years
Connection method
Threaded connection
Environmental temperature
5-55
Temperature range
4-95
Environmental class
Class A
Max working pressure
1.6Mpa
Installation position
Supply / Return flow
Communication method
M-BUS lead
Resolution temperature
±0.5
Working power supply
DC 24V, built-in 3.6V lithium battery



Installation Size

Nominal diameter (mm)
Length L (mm)
Width W (mm)
Height H (mm)
DN20
195
85
115
DN25
225
119
115